GSM7352S Version 08.0.2.10 |
适用于以下型号:
GSM7328Sv2、GSM7352Sv2
问题修复(比 8.0.0.25 版本):
- DHCP server IP address size is increased to 2000
- AX744 (CX4) adapter card shown with "Fiber" type in "show port" output incorrectly
- Sometime during firmware upgrade, there might be configuration corruption
- The Spanning Tree Protocol Topology Change Notication (TCN) message in the logs is not saying the port in which TCN is received.
- Stack master system prompt changed when master and backup models are different
- IGMP Querier does not work with routing VLAN,s
- SNMP community string contains special characters not accepted in GUI. but works fine in CLI
- SNMP Spanning Tree Protocol MIB object, dot1dTpFdbTable mibs, are missing
- GUI page show system has wrong fan info
- Error message about temperature "...sensor 235 i2c operation failed" shows up in the logging buffer
- TACACS+:telnet is unable to go into previlege mode when telnet use TACACS+ as enble method
- The help description of DoS (Denied of Service) command is incorrect
- When downgrading from 8.x to 7.x, the switch,s MAC and serial number data would be lost
- boot menu option 13 doesn,t recover password
- AX744 ports need to change the MAC 10G port pre-emphasis and attenuation, otherwise there may be packet drops
- Show interface switchport output missing "packet forwarded by CPU"
- Switch will crash if "username" function is configured
- Device sends IGMP Group Specific Query when IGMP Querier is not enabled.
- Jump links are missing for "routing table" and "ip" in index page
- Unable to goto the corresponding page when click site index->VLAN Routing Configuration
- Online Support/User Guide/the image link on the top right of the GUI page is incorrect.
- LLDP is sending out the wrong management IP address to the remote partner
- The command "show ip pimdm interface stats all" doesn,t show all of interface stats
- Some command pop-up menu on GUI the device view has some issues
- Switch doesn,t accept the session-timeout in port based mode
- Somehow 8.0 logged buffer reports event in the oldest event first
- GUI: failed to show login help page.
- Port Triggered Topology Change should be in u/s/p format
- STP Topology change notification log message are mssing.
- Maximum Number of Remote Connection Sessions should be 5 instead of 4
- GUI MFDB: help information for the MFDB table is incorrect.
- Failed to configure radius accounting server without the accounting server name on GUI
- Crash when configure snmpv3 authentication protocal to be "md5" or "sha"
- DSCP value changed when enable ip-dscp-mapping on a stacking switch
- Unable to upload script from usb to nvram using copy usb://test2.scr nvram:script test2.scr
- COS queue configuration command under LAG virtual inertave was lost after reloading
- traffic-shape command configured under LAG virtual interface was not saved after reboot
- LACP actor priority changed accordingly when system priority changed
- SNMP: trap message still uses the trap community which is deleted.
- Security->ACL->Advanced->IP Rules web page does not show anything regarding IP ACL rules even after configuring ACL rule
- The switch is returning error message while deleting RADIUS server configuration
- Port dvlan configuration page does not display custom ethertype 0x88a8 when set through the web page
- User unable to login into the switch when using "enable" as a authentication method
- Error message pops up when delete all static routes by GUI
- DHCP command ,option 67 ascii xxx, was returning an error mesage
- Support all "ip xxx" commands under LAG virtual interface